 Micrel, Inc.
ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
SY100S336A
SY100S336A
FEATURES
s Max. shift frequency of 700MHz s Clock to Q delay max. of 1100ps s Sn to TC speed improved by 50% s Sn set-up and hold time reduced by more than 50% s IEE min. of -170mA s Industry standard 100K ECL levels s Internal 75K input pull-down resistors s Extended supply voltage option: VEE = -4.2V to -5.5V s Voltage and temperature compensation for improved noise immunity s 50% faster than Fairchild 300K at lower power s Function and pinout compatible with Fairchild F100K s Available in 24-pin CERPACK and 28-pin PLCC packages
DESCRIPTION
The SY100S336A is functionally the same as the SY100S336, but has Sn to TC speed and Sn set-up and hold times significantly improved, allowing for higher clock frequency when used as a cascaded multi-stage counter. The SY100S336A functions either as a modulo-16 up/ down counter or as a 4-bit bidirectional shift register and is designed for use in high-performance ECL systems. Three Select inputs (Sn) are provided for determining the mode of operation. The Function Table lists the available modes of operation. In order to allow cascading for multistage counters, two Count Enable controls (CEP, CET) are provided. The CET input also functions as the Serial Data input (S0) for a shift-up operation, while the D3 input serves as the Serial Data input for the shift-down operation. When the device is in the counting mode, the Terminal Count (TC) goes to a logical LOW when the count reaches 15 for count-up or reaches 0 for count-down. When in the shift mode, the TC output simply repeats the Q3 output. The flexiblity provided by the TC/Q3 output and the D0/ CET input allows these signals to be interconnected from one stage to the next higher stage for multistage counting or shift-up operations. The individual Presets (Pn) allow initialization of the counter by entering data in parallel to preset the counter. A logic HIGH on the Master Reset (MR) overrides all other inputs and asynchronously clears the flip-flops. An additional synchronous Clear is provided, as well as a complement function which synchronously inverts the contents of the flip-flops. All inputs have 75K pulldown resistors.
PIN NAMES
Pin CP CEP D0/CET S0 -- S2 MR VEES VCCA P0 - P3 D3 TC Q0 -- Q3 Q0 -- Q3 Function Clock Pulse Input Count Enable Parallel Input (Active LOW) Serial Data Input/Count Enable Trickle Input (Active LOW) Select Inputs Master Reset Input VEE Substrate VCCO for ECL Outputs Preset Inputs Serial Data Input Terminal Count Output Data Outputs Complementary Data Outputs
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
Rev.: H
Amendment: /0
1
Issue Date: March 2006
Micrel, Inc.
SY100S336A
PACKAGE/ORDERING INFORMATION
P2 P3 VEES Q3 Q3 D3 P1
Ordering Information
Part Number
4 3 2 1 28 27 26 Q2 Q2 VCCA VCC VCC Q1 Q1
11 10 9 8 7 6 5 P0 CP VEE VEES MR S0 S1 12 13 14 15 16 17 18
Package Type F24-1 F24-1 J28-1 J28-1 J28-1 J28-1
Operating Range Commercial Commercial Commercial Commercial Commercial Commercial
Package Marking SY100S336AFC SY100S336AFC SY100S336AJC SY100S336AJC
Lead Finish Sn-Pb Sn-Pb Sn-Pb Sn-Pb
SY100S336AFC SY100S336AFCTR(1) SY100S336AJC SY100S336AJCTR(1) SY100S336AJZ(2) SY100S336AJZTR(1, 2)
Notes:
Top View PLCC J28-1
19 20 21 22 23 24 25
CEP D0/CET VEES TC Q0 Q0 S2
SY100S336AJZ with Matte-Sn Pb-Free bar-line indicator SY100S336AJZ with Matte-Sn Pb-Free bar-line indicator
28-Pin PLCC (J28-1)
S0 MR VEE CP P0 S1
1. Tape and Reel. 2. Pb-Free package is recommended for new designs.
S2 CEP D0/CET TC Q0 Q0
1 2 3 4 5 6
24 23 22 21 20 19 18 Top View Flatpack F24-1 17 16 15 14
P1 P2 P3 D3 Q3 Q3
13 7 8 9 10 11 12 Q1 VCC VCCA Q1 Q2 Q2
24-Pin Cerpack (F24-1)
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY100S336A
BLOCK DIAGRAM
D3
D0/CET
S0 CEP S1 S2
TC
T Q0 T Q0 R T RC
T T Q1
T T Q2 T
R Q1 T TC
R Q2 T TC
T T Q3 T T R Q3 T TC
CP MR
P0 Q0 Q0
P1 Q1 Q1
P2 Q2 Q2
P3 Q3 Q3
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
3
Micrel, Inc.
SY100S336A
TRUTH TABLE(1)
Inputs MR L L L L L L L L L L L L H H H H H H H H H S2 L L L L H H H H H H H H L L L L H H H H H S1 L L H H L L L L H H H H L L H H L L L H H S0 L H L H L L L H L L L H L H L H L L H L H CEP X X X X L H X X L H X X X X X X X X X X X D0/CET X X X X L L H X L L H X X X X X L H X X X D3 X X X X X X X X X X X X X X X X X X X X X CP u u u u u X X u u X X X X X X X X X X X X Q0 Q0 Q0 L L L L L L L L L Q0 Q0 L Q0 P0 Q0 Q1 D0 Q1 P1 Q1 Q2 Q0 Outputs Q2 P2 Q2 Q3 Q1 Q3 P3 Q3 D3 Q2 TC L L D3 Q3* x Q3 Q3 L x H H Q3 Q3 Q3 L L L L L L L L L H H L L L L L H H H H Mode Preset (Parallel Load) Invert Shift Left Shift Right Count Down Count Down with CEP Not Active Count Down with CET Not Active Clear Count Up Count Up with CEP Not Active Count Up with CET Not Active Hold Asynchronous Master Reset
(Q0-3) minus 1 Q1 Q1 L Q2 Q2 L
(Q0-3) plus 1 Q1 Q1 Q1 L L L L L L L L L Q2 Q2 Q2 L L L L L L L L L
NOTE: 1. H = High Voltage Level L = Low Voltage Level X = Don't Care u = LOW-to-HIGH Transition x = L if Q0 - Q3 = LLLL H if Q0 - Q3 LLLL = L if Q0 - Q3 = HHHH H if Q0 - Q3 HHHH * Before the clock, TC is Q3; after the clock, TC is Q2
DC ELECTRICAL CHARACTERISTICS
VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND
Symbol IIH IEE Parameter Input HIGH Current, All Inputs Power Supply Current Min. -- -170 Typ. -- -120 Max. 200 -60 Unit A mA Condition VIN = VIH (Max.) Inputs Open
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
4
Micrel, Inc.
SY100S336A
AC ELECTRICAL CHARACTERISTICS CERPACK
VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND
TA = 0C Symbol fshift tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tTLH tTHL tS Parameter Shift Frequency Propagation Delay CP to Qn, Qn Propagation Delay CP to TC Propagation Delay MR to Qn, Qn Propagation Delay MR to TC Propagation Delay D0/CET to TC Propagation Delay Sn to TC Transition Time 20% to 80%, 80% to 20% Set-up Time D3 Pn D0/CET to CEP Sn MR (Release Time) Hold Time D3 Pn D0/CET to CEP Sn Pulse Width HIGH, CP, MR Min. 700 450 600 500 600 400 400 300 Max. -- 1200 1900 1400 1900 1200 1500 900 TA = +25C Min. 700 450 600 500 600 400 400 300 Max. -- 1200 1900 1400 1900 1200 1500 900 TA = +85C Min. 700 450 600 500 600 400 400 300 Max. -- 1200 1900 1400 1900 1200 1500 900 Unit MHz ps ps ps ps ps ps ps ps 800 800 700 1000 900 200 200 200 -200 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 1000 900 200 200 200 -200 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 1000 900 200 200 200 -200 -- -- -- -- -- -- ps -- -- -- -- 800 ps Condition
tH
tpw (H)
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
5
Micrel, Inc.
SY100S336A
AC ELECTRICAL CHARACTERISTICS PLCC
VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND
TA = 0C Symbol fshift tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tTLH tTHL tS Parameter Shift Frequency Propagation Delay CP to Qn, Qn Propagation Delay CP to TC Propagation Delay MR to Qn, Qn Propagation Delay MR to TC Propagation Delay D0/CET to TC Propagation Delay Sn to TC Transition Time300 20% to 80%, 80% to 20% Set-up Time D3 Pn D0/CET to CEP Sn MR (Release Time) Hold Time D3 Pn D0/CET to CEP Sn Pulse Width HIGH, CP, MR Min. 700 450 600 500 600 400 400 900 Max. -- 1100 1800 1300 1800 1100 1500 300 TA = +25C Min. 700 450 600 500 600 400 400 900 Max. -- 1100 1800 1300 1800 1100 1500 300 TA = +85C Min. 700 450 600 500 600 400 400 900 Max. -- 1100 1800 1300 1800 1100 1500 ps ps 800 800 700 1000 900 200 200 200 -200 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 1000 900 200 200 200 -200 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 1000 900 200 200 200 -200 -- -- -- -- -- -- ps -- -- -- -- 800 ps Unit MHz ps ps ps ps ps ps Condition
tH
tpw (H)
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
6
Micrel, Inc.
SY100S336A
TIMING DIAGRAMS
DATA
0.7 0.1 ns
0.7 0.1 ns -0.95V 80% 50% 20% -1.69V
CLOCK
1/fshift tPHL tPLH
tpw (H)
OUTPUT
50%
tPLH
tPHL
OUTPUT
tTLH
tTHL
Propagation Delay (Clock) and Transition Times
0.7 0.1 ns
0.7 0.1 ns -0.95V 80% 50% 20% -1.69V tS (RELEASE TIME) tpw (H)
MR
CLOCK
50%
tPHL
tPLH
OUTPUT
50%
tPLH
tPHL 80% 50% 20%
OUTPUT
Propagation Delay (Reset)
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
7
Micrel, Inc.
SY100S336A
TIMING DIAGRAMS
0.7 0.1 ns INPUT
0.7 0.1 ns -0.95V 80% 50% 20% -1.69V tPHL tPLH 80% 50% 20% tTLH tTHL
OUTPUT
Propagation Delay (Serial Data, Selects)
INHIBIT COUNT -0.95V CEP 50% -1.69V ENABLE COUNT tH tS -0.95V D3, Pn, Sn 50% -1.69V tH tS -0.95V CLOCK 50% -1.69V
Set-up and Hold Time
Notes: 1. VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND. 2. tS is the minimum time before the transition of the clock that information must be present at the data input. 3. tH is the minimum time after the transition of the clock that information must remain unchanged at the data input.
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
8
Micrel, Inc.
SY100S336A
24-PIN CERPACK (F24-1)
Rev. 03
M9999-032206 hbwhelp@micrel.com or (408) 955-1690
9
Micrel, Inc.
SY100S336A
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser's use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser's own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. (c) 2006 Micrel, Incorporated. M9999-032206 hbwhelp@micrel.com or (408) 955-1690
10


▲Up To Search▲   

 